09 - Appareils et instruments scientifiques et électriques
42 - Services scientifiques, technologiques et industriels, recherche et conception
Produits et services
Laser thermal sample desorption equipment for mass spectrometry; Laboratory instruments for mass spectrometry analysis of samples from biological, food and environmental matrices; Provision of temporary use of non-downloadable computer software to automate the workflow of biological, food and environmental matrix samples for mass spectrometry analysis; Preparation of biological samples for testing and analysis in research laboratories; advice on quantitative analysis solutions for mass spectrometry; Research and development of scientific laboratory instrumentation, in the field of mass spectrometry; Research and development in the field of biotechnologies; Calibration of laboratory instruments; Calibration of pipettes; Research and design in the fields of chemistry; Research and design in the fields of physics;
09 - Appareils et instruments scientifiques et électriques
Produits et services
(1) Instrument de laboratoire pour l'analyse scientifique, nommément appareil de désorption thermale d'échantillon par laser pour la spectrométrie de masse.
09 - Appareils et instruments scientifiques et électriques
42 - Services scientifiques, technologiques et industriels, recherche et conception
Produits et services
(1) Appareils de désorption thermale d'échantillon par laser pour la spectrométrie de masse; Instruments de laboratoire pour l'analyse d'échantillons de matrices biologiques, alimentaires et environnementales par spectrométrie de masse; (1) Fourniture d'une utilisation temporaire d'un logiciel informatique non téléchargeable pour automatiser le flux de travail d'échantillons de matrices biologiques, alimentaires et environnementales pour une analyse par spectrométrie de masse; Préparation d'échantillons biologiques pour essais et analyses dans des laboratoires de recherche; conseils pour solutions d'analyse quantitative pour la spectrométrie de masse; Recherche et développement d'instrumentation scientifique de laboratoire nommément pour la spectrométrie de masse; Recherche et développement dans le domaine des biotechnologies; Étalonnage d'instruments de laboratoire; Étalonnage de pipettes; Recherche et conception dans les domaines de la chimie; Recherche et la conception dans les domaines de la physique;
9.
Methods and systems for detecting and quantifying a target analyte in a sample by negative ion mode mass spectrometry
H01J 49/04 - Dispositions pour introduire ou extraire les échantillons devant être analysés, p. ex. fermetures étanches au videDispositions pour le réglage externe des composants électronoptiques ou ionoptiques
G01N 27/623 - Spectrométrie de mobilité ionique combinée à la spectrométrie de masse
G01N 27/624 - Spectrométrie de mobilité ionique différentielle [DMS]Spectrométrie de mobilité ionique à haut champ asymétrique [FAIMS]
H01J 49/26 - Spectromètres de masse ou tubes séparateurs de masse
Laser diode thermal desorption coupled with tandem mass spectrometry systems and methods are described to detect at least one target analyte in a sample by negative ion mode mass spectrometry. For instance, the system and method involve desorbing a sample prepared for mass spectrometry analysis by laser diode thermal desorption to obtain a desorbed sample, and then ionizing the desorbed sample under conditions to generate an ionized analyte flow comprising a superoxide radical anion (O2?-) adduct detectable by negative ion mode mass spectrometry; and then detecting the O2?- adduct by negative ion mode mass spectrometry, to thereby detect the target analyte.
H01J 49/04 - Dispositions pour introduire ou extraire les échantillons devant être analysés, p. ex. fermetures étanches au videDispositions pour le réglage externe des composants électronoptiques ou ionoptiques
G01N 27/623 - Spectrométrie de mobilité ionique combinée à la spectrométrie de masse
G01N 27/624 - Spectrométrie de mobilité ionique différentielle [DMS]Spectrométrie de mobilité ionique à haut champ asymétrique [FAIMS]
A mass spectrometer having a triple ionization interface for ionizing sample components is provided. The ionization interface of the mass spectrometer includes a means for ionizing sample components via electrostatic ionization, atmospheric pressure chemical ionization, and laser diode thermal desorption.
H01J 49/04 - Dispositions pour introduire ou extraire les échantillons devant être analysés, p. ex. fermetures étanches au videDispositions pour le réglage externe des composants électronoptiques ou ionoptiques
A mass spectrometer having a triple ionization interface for ionizing sample components is provided. The ionization interface of the mass spectrometer includes a means for ionizing sample components via electrostatic ionization, atmospheric pressure chemical ionization, and laser diode thermal desorption.
H01J 49/04 - Dispositions pour introduire ou extraire les échantillons devant être analysés, p. ex. fermetures étanches au videDispositions pour le réglage externe des composants électronoptiques ou ionoptiques
A method for detecting boar taint in a fat sample is provided. The method includes extracting boar taint compounds from the fat sample to obtain a boar taint extract which includes indole components and androstenone. The method also includes derivatizing the indole components such that the derivatized indole components have a lower volatility than the indole components. The method also includes desorbing the derivatized indole components and the androstenone by Laser Diode Thermal Desorption (LDTD), and ionizing the desorbed analytes. The content of boar taint compounds in the fat sample can then be determined by subjecting the ionized analytes to mass spectrometry.
09 - Appareils et instruments scientifiques et électriques
Produits et services
(1) Instruments de laboratoire pour l'analyse scientifique, nommément appareils de désorption thermale d'échantillon par laser pour la spectrométrie de masse.
16.
Quantification of an analyte in serum and other biological matrices
Methods and systems for quantifying analytes in a biological sample are provided comprising preparing a biological sample for mass spectrometric analysis, utilizing an ionization source to ionize at least a portion of the prepared biological sample to generate an ionized analyte flow, introducing the ionized analyte flow into a differential mobility spectrometer set at a compensation voltage selected to extract ionized analyte molecules from the ionized analyte flow, introducing an output analyte flow of the differential mobility spectrometer into a mass spectrometer to detect and quantify analyte ions in the output analyte flow.
H01J 49/04 - Dispositions pour introduire ou extraire les échantillons devant être analysés, p. ex. fermetures étanches au videDispositions pour le réglage externe des composants électronoptiques ou ionoptiques
G01N 33/82 - Analyse chimique de matériau biologique, p. ex. de sang ou d'urineTest par des méthodes faisant intervenir la formation de liaisons biospécifiques par ligandsTest immunologique faisant intervenir des vitamines
H01J 49/36 - Spectromètres à radio-fréquence, p. ex. spectromètres du type BennettSpectromètres du type Redhead
H01J 49/00 - Spectromètres pour particules ou tubes séparateurs de particules
H01J 49/16 - Sources d'ionsCanons à ions utilisant une ionisation de surface, p. ex. émission thermo-ionique ou photo-électrique
G01N 27/62 - Recherche ou analyse des matériaux par l'emploi de moyens électriques, électrochimiques ou magnétiques en recherchant l'ionisation des gaz, p. ex. des aérosolsRecherche ou analyse des matériaux par l'emploi de moyens électriques, électrochimiques ou magnétiques en recherchant les décharges électriques, p. ex. l'émission cathodique
17.
QUANTIFICATION OF AN ANALYTE IN SERUM AND OTHER BIOLOGICAL MATRICES
Methods and systems for quantifying analytes in a biological sample are provided comprising preparing a biological sample for mass spectrometric analysis, utilizing an ionization source to ionize at least a portion of the prepared biological sample to generate an ionized analyte flow, introducing the ionized analyte flow into a differential mobility spectrometer set at a compensation voltage selected to extract ionized analyte molecules from the ionized analyte flow, introducing an output analyte flow of the differential mobility spectrometer into a mass spectrometer to detect and quantify analyte ions in the output analyte flow.
Methods and systems for quantifying analytes in a biological sample are provided comprising preparing a biological sample for mass spectrometric analysis, utilizing an ionization source to ionize at least a portion of the prepared biological sample to generate an ionized analyte flow, introducing the ionized analyte flow into a differential mobility spectrometer set at a compensation voltage selected to extract ionized analyte molecules from the ionized analyte flow, introducing an output analyte flow of the differential mobility spectrometer into a mass spectrometer to detect and quantify analyte ions in the output analyte flow.
G01N 27/62 - Recherche ou analyse des matériaux par l'emploi de moyens électriques, électrochimiques ou magnétiques en recherchant l'ionisation des gaz, p. ex. des aérosolsRecherche ou analyse des matériaux par l'emploi de moyens électriques, électrochimiques ou magnétiques en recherchant les décharges électriques, p. ex. l'émission cathodique
H01J 49/26 - Spectromètres de masse ou tubes séparateurs de masse
19.
SAMPLE PREPARATION FOR MASS SPECTROMETRY ANALYSIS SYSTEMS
The present invention relates to the preparation of samples for subsequent analysis, in particular for mass spectrometry analysis, and may for example replace traditional dried blood spot (DBS) or dried plasma spot (DPS) techniques. Methods according to the invention generally involve collecting the sample in a sampling tip and extracting the sample from this sampling tip, for example through injection into wells of the analytical system through which the sample is to be analysed. A sampling tip is provided and has a hollow body with opposite open extremities respectively defining input and output ends and a cavity between these extremities. A filling material provided within the cavity for receiving the sample from the input end of the body, while the output end is designed to allow an extraction of the sample therefrom. Collecting, extracting and overall sample preparation methods are also provided.
G01N 1/28 - Préparation d'échantillons pour l'analyse
G01N 35/00 - Analyse automatique non limitée à des procédés ou à des matériaux spécifiés dans un seul des groupes Manipulation de matériaux à cet effet
09 - Appareils et instruments scientifiques et électriques
Produits et services
(1) Instrument de laboratoire pour l'analyse scientifique, nommément appareil de désorption thermale d'échantillon par laser pour la spectrométrie de masse.
An apparatus and method for regenerating ion samples for a mass spectrometer are provided. Source samples are loaded on a support which is heated by a laser beam, desorbing the sample without ionization. The desorbed sample is carried by a carrier gas flow through a transfer tube, at the output of which it is ionized by corona discharge or photo-ionization. The obtained ionized sample may be analyzed in a mass spectrometer or used to serve any other appropriate purpose.
H01J 49/04 - Dispositions pour introduire ou extraire les échantillons devant être analysés, p. ex. fermetures étanches au videDispositions pour le réglage externe des composants électronoptiques ou ionoptiques
An apparatus and method for regenerating ion samples for a mass spectrometer are provided. Source samples are loaded on a support which is heated by a laser beam, desorbing the sample without ionization. The desorbed sample is carried by a carrier gas flow through a transfer tube, at the output of which it is ionized by corona discharge or photo-ionization. The obtained ionized sample may be analyzed in a mass spectrometer or used to serve any other appropriate purpose.