09 - Appareils et instruments scientifiques et électriques
42 - Services scientifiques, technologiques et industriels, recherche et conception
Produits et services
Downloadable mobile applications for use in remotely
monitoring and managing performance of an ambulatory medical
pump, troubleshooting issues with performance of an
ambulatory medical pump, locating an ambulatory medical
pump, and purchasing products used by an ambulatory medical
pump. Providing temporary use of online non-downloadable mobile
application that give users the ability to remotely monitor
and manage performance of an ambulatory medical pump,
troubleshoot issues with performance of an ambulatory
medical pump, locate an ambulatory medical pump, and
purchase products used by an ambulatory medical pump via a
website; providing non-downloadable computer software that
gives users the ability to remotely monitor and manage
performance of an ambulatory medical pump, troubleshoot
issues with performance of an ambulatory medical pump,
locate an ambulatory medical pump, and purchase products
used by an ambulatory medical pump via a website.
09 - Appareils et instruments scientifiques et électriques
42 - Services scientifiques, technologiques et industriels, recherche et conception
Produits et services
(1) Downloadable mobile applications for use in remotely monitoring and managing performance of an ambulatory medical pump, namely software as a medical device [SaMD], downloadable, for adjusting infusion pump, insulin pump and enteral feeding pump settings based on personalized patient data, downloadable software applications for performing diagnostics and troubleshooting to diagnose issues with performance of a medical infusion pump, insulin pump and enteral feeding pump, downloadable mobile application software for locating medical infusion pumps, insulin pumps and enteral feeding pumps and purchasing products for use with medical infusion pumps, insulin pumps and enteral feedings pumps. (1) Providing temporary use of online non-downloadable mobile software applications that give users the ability to remotely monitor and manage performance of medical infusion pumps, insulin pumps and enteral feeding pumps, providing temporary use of online non-downloadable mobile software applications for troubleshooting in the nature of diagnosing mobile software application performance issues of medical infusion pumps, insulin pumps and enteral feeding pumps, providing temporary use of online non-downloadable mobile software applications for locating medical infusion pumps, insulin pumps and enteral feeding pumps and purchase products for use with medical infusion pumps, insulin pumps and enteral feedings pumps via a website; providing non-downloadable computer software to allow users the ability to remotely monitor and manage performance of medical infusion pumps, insulin pumps and enteral feedings pumps, troubleshoot issues with performance of medical infusion pumps, insulin pumps and enteral feedings pumps, providing non-downloadable computer software to allow users to locate medical infusion pumps, insulin pumps and enteral feedings pumps and purchase products for use with medical infusion pumps, insulin pumps and enteral feedings pumps via a website.
09 - Appareils et instruments scientifiques et électriques
42 - Services scientifiques, technologiques et industriels, recherche et conception
Produits et services
Downloadable mobile applications for use in remotely monitoring and managing performance of an ambulatory medical pump, troubleshooting issues with performance of an ambulatory medical pump, locating an ambulatory medical pump, and purchasing products used by an ambulatory medical pump Providing a website featuring technology that give users the ability to remotely monitor and manage performance of an ambulatory medical pump, troubleshoot issues with performance of an ambulatory medical pump, locate an ambulatory medical pump, and purchase products used by an ambulatory medical pump via a website
A pumping finger subassembly for a peristaltic infusion pump has a housing, a pinch member, a block member, and at least one biasing spring. The housing includes a transverse slot, a first side wall, and an open second side through which the pinch member and biasing spring(s) are inserted into the transverse slot. The block member includes a foot portion and a side wall portion. The foot portion is insertable into the housing through the open second side such that the block member is constrained against movement relative to the housing and the side wall portion of the block member opposes the first side wall of the housing, whereby the pinch member is supported on both lateral sides to prevent tilting of the pinch member.
A pumping finger subassembly for a peristaltic infusion pump has a housing, a pinch member, a block member, and at least one biasing spring. The housing includes a transverse slot, a first side wall, and an open second side through which the pinch member and biasing spring(s) are inserted into the transverse slot. The block member includes a foot portion and a side wall portion. The foot portion is insertable into the housing through the open second side such that the block member is constrained against movement relative to the housing and the side wall portion of the block member opposes the first side wall of the housing, whereby the pinch member is supported on both lateral sides to prevent tilting of the pinch member.
F04B 43/12 - "Machines", pompes ou installations de pompage ayant des organes de travail flexibles à action péristaltique
A61M 5/142 - Perfusion sous pression, p. ex. utilisant des pompes
A61M 5/168 - Moyens pour commander l'écoulement des agents vers le corps ou pour doser les agents à introduire dans le corps, p. ex. compteurs de goutte-à-goutte
F04B 45/08 - Pompes ou installations de pompage, ayant des organes de travail flexibles, spécialement adaptées pour fluides compressibles à action péristaltique
A pumping finger subassembly for a peristaltic infusion pump has a housing, a pinch member, a block member, and at least one biasing spring. The housing includes a transverse slot, a first side wall, and an open second side through which the pinch member and biasing spring(s) are inserted into the transverse slot. The block member includes a foot portion and a side wall portion. The foot portion is insertable into the housing through the open second side such that the block member is constrained against movement relative to the housing and the side wall portion of the block member opposes the first side wall of the housing, whereby the pinch member is supported on both lateral sides to prevent tilting of the pinch member.
A platen assembly positionable opposite a pumping mechanism of an infusion pump has a first platen member rotatably coupled to the pump to pivot about a first hinge axis and a second platen member rotatably coupled to the first platen member to pivot about a second hinge axis different from the first hinge axis. When the platen assembly is in a pump operating position, respective platen surfaces of the platen members follow a single surface profile, for example an arcuate surface profile in the case of a curvilinear peristaltic pump. The platen assembly may have a damage-tolerant design including a plurality of alignment counter-features arranged to mate with corresponding alignment features on the pump, wherein the platen assembly may still close after the pump is dropped or damaged only if resulting deformation of the platen assembly is within an allowable tolerance for safe pumping.
A platen assembly positionable opposite a pumping mechanism of an infusion pump has a first platen member rotatably coupled to the pump to pivot about a first hinge axis and a second platen member rotatably coupled to the first platen member to pivot about a second hinge axis different from the first hinge axis. When the platen assembly is in a pump operating position, respective platen surfaces of the platen members follow a single surface profile, for example an arcuate surface profile in the case of a curvilinear peristaltic pump. The platen assembly may have a damage-tolerant design including a plurality of alignment counter-features arranged to mate with corresponding alignment features on the pump, wherein the platen assembly may still close after the pump is dropped or damaged only if resulting deformation of the platen assembly is within an allowable tolerance for safe pumping.
An infusion pump apparatus includes a length of resilient tubing removably loadable in an infusion pump having a housing, a pumping mechanism, and a pump door. A latch member is pivotally mounted to the pump door and cooperates with a latch pin fixed on pump housing. A free-flow protection device is biased to pinch the tubing closed to stop fluid flow. The latch member has a first range of pivotal motion in a latching direction for causing the latch member to engage with the latch pin to secure the door in a closed position and a second range of pivotal motion in the latching direction for causing the latch member to actuate the free-flow protection device to unpinch the tubing and allow flow. The latch member pivots through at least a portion of the first range of pivotal motion before beginning to pivot through the second range of pivotal motion.
A61M 5/168 - Moyens pour commander l'écoulement des agents vers le corps ou pour doser les agents à introduire dans le corps, p. ex. compteurs de goutte-à-goutte
A61M 5/142 - Perfusion sous pression, p. ex. utilisant des pompes
An administration set for an infusion pump includes a free-flow prevention device having a movable plunger that includes a cam surface defining an uneven profile along a direction of movement of the plunger, wherein the shape of the cam surface profile indicates the administration set is authorized for use with the infusion pump and may further indicate the specific type of administration set. A sensor in the infusion pump senses movement of the plunger as a platen of the infusion pump is latched and generates a profile signal in the time domain representative of the cam surface profile. A processor evaluates the profile signal and controls operation of the pump to protect a patient from improper loading of an administration set, use of an unauthorized administration set, and/or use of an invalid type of administration set for a chosen infusion protocol.
A61M 5/168 - Moyens pour commander l'écoulement des agents vers le corps ou pour doser les agents à introduire dans le corps, p. ex. compteurs de goutte-à-goutte
G16H 40/63 - TIC spécialement adaptées à la gestion ou à l’administration de ressources ou d’établissements de santéTIC spécialement adaptées à la gestion ou au fonctionnement d’équipement ou de dispositifs médicaux pour le fonctionnement d’équipement ou de dispositifs médicaux pour le fonctionnement local
A61M 5/142 - Perfusion sous pression, p. ex. utilisant des pompes
G16H 20/17 - TIC spécialement adaptées aux thérapies ou aux plans d’amélioration de la santé, p. ex. pour manier les prescriptions, orienter la thérapie ou surveiller l’observance par les patients concernant des médicaments ou des médications, p. ex. pour s’assurer de l’administration correcte aux patients administrés par perfusion ou injection
20.
Administration set detection and authentication using cam profiles
An administration set for an infusion pump includes a free-flow prevention device having a movable plunger that includes a cam surface defining an uneven profile along a direction of movement of the plunger, wherein the shape of the cam surface profile indicates the administration set is authorized for use with the infusion pump and may further indicate the specific type of administration set. A sensor in the infusion pump senses movement of the plunger as a platen of the infusion pump is latched and generates a profile signal in the time domain representative of the cam surface profile. A processor evaluates the profile signal and controls operation of the pump to protect a patient from improper loading of an administration set, use of an unauthorized administration set, and/or use of an invalid type of administration set for a chosen infusion protocol.
A61M 5/168 - Moyens pour commander l'écoulement des agents vers le corps ou pour doser les agents à introduire dans le corps, p. ex. compteurs de goutte-à-goutte
A61M 5/142 - Perfusion sous pression, p. ex. utilisant des pompes
G16H 40/63 - TIC spécialement adaptées à la gestion ou à l’administration de ressources ou d’établissements de santéTIC spécialement adaptées à la gestion ou au fonctionnement d’équipement ou de dispositifs médicaux pour le fonctionnement d’équipement ou de dispositifs médicaux pour le fonctionnement local
G16H 20/17 - TIC spécialement adaptées aux thérapies ou aux plans d’amélioration de la santé, p. ex. pour manier les prescriptions, orienter la thérapie ou surveiller l’observance par les patients concernant des médicaments ou des médications, p. ex. pour s’assurer de l’administration correcte aux patients administrés par perfusion ou injection
21.
INFUSION PUMP LATCH MECHANISM AND ASSOCIATED FREE-FLOW PROTECTION DEVICE
An infusion pump apparatus includes a length of resilient tubing removably loadable in an infusion pump having a housing, a pumping mechanism, and a pump door. A latch member is pivotally mounted to the pump door and cooperates with a latch pin fixed on pump housing. A free-flow protection device is biased to pinch the tubing closed to stop fluid flow. The latch member has a first range of pivotal motion in a latching direction for causing the latch member to engage with the latch pin to secure the door in a closed position and a second range of pivotal motion in the latching direction for causing the latch member to actuate the free-flow protection device to unpinch the tubing and allow flow. The latch member pivots through at least a portion of the first range of pivotal motion before beginning to pivot through the second range of pivotal motion.
A61M 5/175 - Moyens pour commander l'écoulement des agents vers le corps ou pour doser les agents à introduire dans le corps, p. ex. compteurs de goutte-à-goutte mécaniques
22.
Infusion pump latch mechanism and associated free-flow protection device
An infusion pump apparatus includes a length of resilient tubing removably loadable in an infusion pump having a housing, a pumping mechanism, and a pump door. A latch member is pivotally mounted to the pump door and cooperates with a latch pin fixed on pump housing. A free-flow protection device is biased to pinch the tubing closed to stop fluid flow. The latch member has a first range of pivotal motion in a latching direction for causing the latch member to engage with the latch pin to secure the door in a closed position and a second range of pivotal motion in the latching direction for causing the latch member to actuate the free-flow protection device to unpinch the tubing and allow flow. The latch member pivots through at least a portion of the first range of pivotal motion before beginning to pivot through the second range of pivotal motion.
A61M 5/168 - Moyens pour commander l'écoulement des agents vers le corps ou pour doser les agents à introduire dans le corps, p. ex. compteurs de goutte-à-goutte
A61M 5/142 - Perfusion sous pression, p. ex. utilisant des pompes
An administration set for an infusion pump includes a free-flow prevention device having a movable plunger that includes a cam surface defining an uneven profile along a direction of movement of the plunger, wherein the shape of the cam surface profile indicates the administration set is authorized for use with the infusion pump and may further indicate the specific type of administration set. A sensor in the infusion pump senses movement of the plunger as a platen of the infusion pump is latched and generates a profile signal in the time domain representative of the cam surface profile. A processor evaluates the profile signal and controls operation of the pump to protect a patient from improper loading of an administration set, use of an unauthorized administration set, and/or use of an invalid type of administration set for a chosen infusion protocol.
An administration set for an infusion pump includes a free-flow prevention device having a movable plunger that includes a cam surface defining an uneven profile along a direction of movement of the plunger, wherein the shape of the cam surface profile indicates the administration set is authorized for use with the infusion pump and may further indicate the specific type of administration set. A sensor in the infusion pump senses movement of the plunger as a platen of the infusion pump is latched and generates a profile signal in the time domain representative of the cam surface profile. A processor evaluates the profile signal and controls operation of the pump to protect a patient from improper loading of an administration set, use of an unauthorized administration set, and/or use of an invalid type of administration set for a chosen infusion protocol.
A61M 5/142 - Perfusion sous pression, p. ex. utilisant des pompes
A61M 5/168 - Moyens pour commander l'écoulement des agents vers le corps ou pour doser les agents à introduire dans le corps, p. ex. compteurs de goutte-à-goutte
G16H 40/63 - TIC spécialement adaptées à la gestion ou à l’administration de ressources ou d’établissements de santéTIC spécialement adaptées à la gestion ou au fonctionnement d’équipement ou de dispositifs médicaux pour le fonctionnement d’équipement ou de dispositifs médicaux pour le fonctionnement local
A system for tracing tubing which forms a conduit from a source of infusion liquid to a patient by way of an infusion pump has a vibration generator manually operable by a user to generate vibrations at an origin location along the tubing, wherein the vibrations are propagated by the tubing and have a vibration signature. A vibration sensor arranged at a destination location along the tubing receives the vibrations and generates a digital vibration signal. Signal processing circuitry connected to the vibration sensor processes and evaluates the digital vibration signal to determine a trace status of the tubing between the vibration generator and the vibration sensor. An indicator connected to the signal processing circuitry provides an indication of the determined trace status. Trace status possibilities include clear, cross-over, and null. A likely number of cross-overs may also be indicated.
A system for tracing tubing which forms a conduit from a source of infusion liquid to a patient by way of an infusion pump has a vibration generator manually operable by a user to generate vibrations at an origin location along the tubing, wherein the vibrations are propagated by the tubing and have a vibration signature. A vibration sensor arranged at a destination location along the tubing receives the vibrations and generates a digital vibration signal. Signal processing circuitry connected to the vibration sensor processes and evaluates the digital vibration signal to determine a trace status of the tubing between the vibration generator and the vibration sensor. An indicator connected to the signal processing circuitry provides an indication of the determined trace status. Trace status possibilities include clear, cross-over, and null. A likely number of cross-overs may also be indicated.
A61M 5/142 - Perfusion sous pression, p. ex. utilisant des pompes
A61M 5/50 - Dispositifs pour faire pénétrer des agents dans le corps par introduction sous-cutanée, intravasculaire ou intramusculaireAccessoires à cet effet, p. ex. dispositifs de remplissage ou de nettoyage, appuis-bras avec des moyens pour empêcher la réutilisation ou pour indiquer si le dispositif est défectueux, usagé, non stérile ou si l'on a tenté de l'utiliser
A61M 5/14 - Dispositifs de perfusion, p. ex. perfusion par gravitéPerfusion sanguineAccessoires à cet effet
A61M 39/08 - TubesMoyens de rangement spécialement adaptés aux tubes
G06F 19/00 - Équipement ou méthodes de traitement de données ou de calcul numérique, spécialement adaptés à des applications spécifiques (spécialement adaptés à des fonctions spécifiques G06F 17/00;systèmes ou méthodes de traitement de données spécialement adaptés à des fins administratives, commerciales, financières, de gestion, de surveillance ou de prévision G06Q;informatique médicale G16H)
28.
SYSTEMS AND METHODS FOR VALIDATING TREATMENT INSTRUCTIONS
The present invention can be described as systems and methods for validating treatment instructions. The system may comprise a server having a library database and an agency interface configured to receive medical treatment guidelines and store medical treatment guidelines in the library database. The system may also comprise an administrative console, a processor and a medical device. The processor is configured to validate a treatment instruction of the medical device based on the medical treatment guidelines in the library database. As a method, the present invention receives updated medical information and a treatment instruction of the medical device. Using the processor the treatment instruction is validated based on the medical information of the library database and a validation message is transmitted to the medical device.
A peristaltic pump assembly comprises a pump and a removable cassette. The pump includes a pumping mechanism portion having opposed inner and outer walls defining a slot opening therebetween, and further having a cassette mounting pin extending at least partially across the slot opening. The removable cassette includes a cylindrical hinge journal and a mounting channel merging in a radial direction with the hinge journal, whereby the cassette is mounted on the mounting pin by inserting the removable cassette into the slot opening between the inner and outer walls of the pumping mechanism portion in a radial direction of the mounting pin such that the mounting pin is passed through the mounting channel and received by the hinge journal. The mounting pin and hinge journal are configured to allow the removable cassette to rotate about the mounting pin into and out of an installed position.
A peristaltic pump assembly comprises a pump and a removable cassette. The pump includes a pumping mechanism portion having opposed inner and outer walls defining a slot opening therebetween, and further having a cassette mounting pin extending at least partially across the slot opening. The removable cassette includes a cylindrical hinge journal and a mounting channel merging in a radial direction with the hinge journal, whereby the cassette is mounted on the mounting pin by inserting the removable cassette into the slot opening between the inner and outer walls of the pumping mechanism portion in a radial direction of the mounting pin such that the mounting pin is passed through the mounting channel and received by the hinge journal. The mounting pin and hinge journal are configured to allow the removable cassette to rotate about the mounting pin into and out of an installed position.
A system and method for preventing an undesirable reverse rotation of an infusion pump assembly. The infusion pump motor includes a roller assembly, a coil, a rotor, a rotor position sensor, and a controller. The rotor is in communication with the coil, and the rotor is rotationally coupled to a roller assembly. If the pump is in not pumping, then the system monitors for reverse rotation of the pump, and if reverse rotation of the pump is detected, energizes the coil in a manner that holds the rotor in place. The system may also activate an indicator if reverse rotation is detected.
A61M 31/00 - Dispositifs pour l'introduction ou la rétention d'agents, p. ex. de remèdes, dans les cavités du corps
F04B 43/00 - "Machines", pompes ou installations de pompage ayant des organes de travail flexibles
F04B 43/08 - "Machines", pompes ou installations de pompage ayant des organes de travail flexibles ayant des organes flexibles tubulaires
F04B 43/12 - "Machines", pompes ou installations de pompage ayant des organes de travail flexibles à action péristaltique
F04B 45/06 - Pompes ou installations de pompage, ayant des organes de travail flexibles, spécialement adaptées pour fluides compressibles ayant des organes flexibles tubulaires
A syringe holder is provided for mounting syringe while the syringe is distributing fluid. The syringe holder includes a hook, a main body, and a receiver. The receiver is operatively configured to deploy away from the main body when the syringe is disposed in the receiver.
A method of automatically programming an infusion pump includes scanning, via a machine-readable scanner wirelessly connected to the infusion pump, a machine-readable label for a drug container to automatically program the infusion pump according to a protocol included in the label. The machine-readable label for the drug container further includes a drug name and data associated with a drug corresponding to the drug name.
G06Q 50/00 - Technologies de l’information et de la communication [TIC] spécialement adaptées à la mise en œuvre des procédés d’affaires d’un secteur particulier d’activité économique, p. ex. aux services d’utilité publique ou au tourisme
A tool or computer-readable medium for interfacing with an infusion pump includes i) computer-readable code for generating a drug library, generating a run profile, or a combination thereof, and ii) computer-readable code for configuring the infusion pump.
A61M 5/142 - Perfusion sous pression, p. ex. utilisant des pompes
A61M 5/145 - Perfusion sous pression, p. ex. utilisant des pompes utilisant des réservoirs sous pression, p. ex. au moyen de pistons
G06F 19/00 - Équipement ou méthodes de traitement de données ou de calcul numérique, spécialement adaptés à des applications spécifiques (spécialement adaptés à des fonctions spécifiques G06F 17/00;systèmes ou méthodes de traitement de données spécialement adaptés à des fins administratives, commerciales, financières, de gestion, de surveillance ou de prévision G06Q;informatique médicale G16H)
35.
Alarm identification system for infusion set when installed in pump assembly
Disclosed herein is an identification system for an infusion set when the infusion set is installed in a pump. The identification system includes a pump, at least one sensor, a catheter, a tube and an alarm. The pump includes at least one sensor disposed thereon, which is in communication with the alarm. The catheter includes a distal end adapted for insertion into a body, and a proximal end opposite the distal end. The tube is operatively configured at a first end to removeably attach to the proximal end of the catheter, and the tube further includes a second end proximate to the sensor(s) on the pump. The sensor(s) are operatively configured to receive a signal generated at the first end or along a length of the tube, and to trigger the alarm upon receiving the signal so as to identify the corresponding pump.
A61M 5/142 - Perfusion sous pression, p. ex. utilisant des pompes
A61B 19/00 - Instruments, outillage ou accessoires pour la chirurgie ou le diagnostic non couverts par l'un des groupes A61B 1/00-A61B 18/00, p.ex. pour stéréotaxie, opération aseptique, traitement de la luxation, protecteurs des bords des blessures(masques de protection du visage A41D 13/11; blouses de chirurgien ou vêtements pour malades A41D 13/12; dispositifs pour retirer, traiter ou transporter les liquides du corps A61M 1/00)
A61M 5/172 - Moyens pour commander l'écoulement des agents vers le corps ou pour doser les agents à introduire dans le corps, p. ex. compteurs de goutte-à-goutte électriques ou électroniques
A tool or computer-readable medium for interfacing with an infusion pump includes i) computer-readable code for generating a drug library, generating a run profile, or a combination thereof, and ii) computer-readable code for configuring the infusion pump.
G06F 19/00 - Équipement ou méthodes de traitement de données ou de calcul numérique, spécialement adaptés à des applications spécifiques (spécialement adaptés à des fonctions spécifiques G06F 17/00;systèmes ou méthodes de traitement de données spécialement adaptés à des fins administratives, commerciales, financières, de gestion, de surveillance ou de prévision G06Q;informatique médicale G16H)
A single piece gasket is provided wherein the single piece gasket includes a gasket member first portion and a gasket member second portion integral to the gasket member first portion. The gasket member first and second portions are in a common plane when the gasket member is in a relaxed state, and the first and second portions are in intersecting planes in a flexed state. The gasket member first portion is operatively configured to seal at least two compartments. The first and gasket member second portions have substantially circular cross- sections.
Disclosed herein is an identification system for an infusion set when the infusion set is installed in a pump. The identification system includes a pump, at least one sensor, a catheter, a tube and an alarm. The pump includes at least one sensor disposed thereon, which is in communication with the alarm. The catheter includes a distal end adapted for insertion into a body, and a proximal end opposite the distal end. The tube is operatively configured at a first end to removeably attach to the proximal end of the catheter, and the tube further includes a second end proximate to the sensor(s) on the pump. The sensor(s) are operatively configured to receive a signal generated at the first end or along a length of the tube, and to trigger the alarm upon receiving the signal so as to identify the corresponding pump.
A61M 5/172 - Moyens pour commander l'écoulement des agents vers le corps ou pour doser les agents à introduire dans le corps, p. ex. compteurs de goutte-à-goutte électriques ou électroniques
A syringe holder is provided for mounting syringe while the syringe is distributing fluid. The syringe holder includes a hook, a main body, and a receiver. The receiver is operatively configured to deploy away from the main body when the syringe is disposed in the receiver.
A61M 5/00 - Dispositifs pour faire pénétrer des agents dans le corps par introduction sous-cutanée, intravasculaire ou intramusculaireAccessoires à cet effet, p. ex. dispositifs de remplissage ou de nettoyage, appuis-bras
40.
METHOD OF AUTOMATICALLY PROGRAMMING AN INFUSION PUMP
A method of automatically programming an infusion pump includes scanning, via a machine-readable scanner wirelessly connected to the infusion pump, a machine-readable label for a drug container to automatically program the infusion pump according to a protocol included in the label. The machine-readable label for the drug container further includes a drug name and data associated with a drug corresponding to the drug name.
G06F 19/00 - Équipement ou méthodes de traitement de données ou de calcul numérique, spécialement adaptés à des applications spécifiques (spécialement adaptés à des fonctions spécifiques G06F 17/00;systèmes ou méthodes de traitement de données spécialement adaptés à des fins administratives, commerciales, financières, de gestion, de surveillance ou de prévision G06Q;informatique médicale G16H)
41.
METHOD OF LOADING A DRUG LIBRARY INTO AN INFUSION PUMP
A method of loading a drug library into an infusion pump includes transferring the drug library, stored on a remote device, to the infusion pump via a wireless connection. The drug library includes a plurality of subdirectories, and each subdirectory includes a care area, at least one drug, data associated with and dependent upon the drug(s), and at least one mode of operation for infusing the drug(s).
A61M 37/00 - Autres appareils pour introduire des agents dans le corpsPercutanisation, c.-à-d. introduction de médicaments dans le corps par diffusion à travers la peau
42.
INFUSION PUMP ASSEMBLY HAVING A REVERSE ROTATION PREVENTION SYSTEM AND METHOD FOR OPERATING THE SAME
A system and method for preventing an undesirable reverse rotation of an infusion pump assembly. The infusion pump motor includes a roller assembly, a coil, a rotor, a rotor position sensor, and a controller. The rotor is in communication with the coil, and the rotor is rotationally coupled to a roller assembly. If the pump is in not pumping, then the system monitors for reverse rotation of the pump, and if reverse rotation of the pump is detected, energizes the coil in a manner that holds the rotor in place. The system may also activate an indicator if reverse rotation is detected.
A method of inputting data into an infusion pump includes inputting the data into a user interface using a data entry system. The user interface includes i) the data entry system for inputting the data related to a drug, a subject, a caregiver, and a protocol for infusing the drug to the subject, ii) a display operative associated with the data entry system, and iii) a processor operatively associated with the display and the data entry system, where the processor has stored therein a program for prompting a user of the infusion pump, via a screen presented on the display, for respective data entry.
A method of fluid delivery from a rotary peristaltic pump is provided. It comprises providing a roller assembly having a plurality of rollers, the roller assembly having at least one anomalous range and determining a rotational position of the plurality of rollers. The method further comprises increasing a speed of the plurality of rollers when at least one of the plurality of rollers are in the anomalous range and decreasing the speed of the plurality of rollers when each of the plurality of rollers are outside the anomalous range.
A removable cassette for a peristaltic pump includes a cassette body and an occluder disposed at least partially in the cassette body and configured to be movable between an occluding position and a non-occluding position. The occluder includes an occluder body and an anti-ejection member integrally formed on the occluder body. The anti-ejection member is configured to substantially prevent the removal of the cassette from the peristaltic pump when the occluder is in the non-occluding position.
F04B 43/08 - "Machines", pompes ou installations de pompage ayant des organes de travail flexibles ayant des organes flexibles tubulaires
F04B 43/12 - "Machines", pompes ou installations de pompage ayant des organes de travail flexibles à action péristaltique
F04B 45/06 - Pompes ou installations de pompage, ayant des organes de travail flexibles, spécialement adaptées pour fluides compressibles ayant des organes flexibles tubulaires
A peristaltic pump assembly includes a pump body and a cassette removably attached thereto, wherein the cassette includes a race configured to provide a compression surface for a tube supported by the cassette. A roller assembly is operatively connected to the pump body, wherein the roller assembly includes a plurality of rollers configured to apply a predetermined force to the tube, thereby compressing the tube against the race. The peristaltic pump assembly further includes a regulator disposed in the pump body and operatively connected to the cassette, where the regulator is configured to regulate the predetermined force applied to the tube.
An infusion pump having a plurality of function keys which initiate different processes depending on the state of the infusion pump is disclosed. In the configuration state, the function keys operate to set the various configurable options with regard to the desired medication treatment parameters. In the infusing state, the function keys operate to transmit various operational data to a readout screen depending on the function key pressed. Essentially, multi-function, state dependent function keys operable on an infusion pump is disclosed.
A61M 37/00 - Autres appareils pour introduire des agents dans le corpsPercutanisation, c.-à-d. introduction de médicaments dans le corps par diffusion à travers la peau
A61M 5/142 - Perfusion sous pression, p. ex. utilisant des pompes
F04B 43/00 - "Machines", pompes ou installations de pompage ayant des organes de travail flexibles
F04B 43/08 - "Machines", pompes ou installations de pompage ayant des organes de travail flexibles ayant des organes flexibles tubulaires
A61M 5/14 - Dispositifs de perfusion, p. ex. perfusion par gravitéPerfusion sanguineAccessoires à cet effet
09 - Appareils et instruments scientifiques et électriques
10 - Appareils et instruments médicaux
Produits et services
Computer software for use by medical professionals for ensuring proper medication delivery, remote monitoring of the infusion process, facilitating infusion pump programming, and facilitating billing, management, and archival storage of client and clinic information Medical apparatus for introducing pharmaceutical preparations into the human body, namely, medical infusion pumps; administration sets consisting primarily of infusion equipment, namely, tubing, luer locks, luer lock caps, bag spikes, Y-sites, check valves, filters, and reservoirs